Fire Fighting System Type | Fire Suppression Systems |
Capacity | As per requirement |
Packaging Type | Set |
System type | Pre-Engineered System |
Type | Fire Extinguisher, Fire Suppression System |
Condition | New |
Material | Mild Steel |
Certification | UL Approved, FM Approved, CE |
Environment Temp | Ambient Tempreture |
Fire Suppression Type | Cylinder |
Working Pressure | 16-18 Bar |
Cylinder Size | Customized |
Usage/Application | Commercial |
Installation Services Required | Yes |
Automation Grade | Automatic |
Is It Portable | Portable |
I Deal In | New Only |
Country of Origin | Made in India |
We are one of the widely acclaimed manufacturers, wholesalers, traders and retailers of Electric Panel Suppression System. The offered electric panel suppression system is specially designed for protecting the high risk electric circuitry and network. Our supplied electric panel suppression system is highly liked by the clients, due to the ease of installation in electric cabinets. The offered electric panel suppression system is very affordable in rates.
Fire Fighting System Type | Fire Suppression Systems |
System type | Pre-Engineered System |
Brand | HD |
Fire Suppression Type | Cylinder |
Operating Temperature Limit | OPERATING 200/300 Bar PRESSURE |
Cylinder Size | CYLINDER SIZES 80 and 140L |
Model Name/Number | SUPPRESSION IG55, IG541, IG100, IG01 AGENT |
I Deal In | New Only |
APPROVAL | VdS Approved |
Country of Origin | Made in India |
INERTSYS® is a specialized Clean Agent Fire Suppression System, utilizing IG55, IG541, IG100, and IG01 Suppressing Agents.
Description
· Designed for IG55 (50% Argon and 50% Nitrogen), IG541 (52% Nitrogen, 40% Argon and 8% Carbon dioxide), IG100 (Nitrogen) and IG01 (Argon) agents
· Gases are colourless, odourless, and electrically nonconductive with a density approximately the same as air
· Cylinder Sizes: 80 and 140 litre
· Operating Pressure: 200 bar (2900 psi), 300 bar (4351 psi), depending on volume and concentration requirements
· Releasing Device: Manual, Pneumatic, Electro-Magnetic
· Available with Selector/Directional valves for protection of multiple areas with a common gas bank
· Approval: VdS
· System Design Calculations performed using VdS calculation software
Fire Fighting System Type | Fire Suppression Systems |
Packaging Type | Carton |
System type | Pre-Engineered System |
Usage/Application | Commercial |
Brand | Firetuff |
Material | Mild Steel |
Fire Suppression Type | Pipeline |
I Deal In | New Only |
Country of Origin | Made in India |
A CNC (Computer Numerical Control) machine fire suppression system is a critical safety feature designed to detect and extinguish fires that may occur during machining operations. Here's a description of its components and functionality:
Detection System: The fire suppression system typically incorporates sensors or detectors strategically placed within the CNC machine and its vicinity to monitor for signs of fire or excessive heat. These sensors can include smoke detectors, heat detectors, flame detectors, or combinations thereof.
Control Panel: The control panel serves as the central hub of the fire suppression system. It receives signals from the detection sensors and activates the suppression mechanisms when a fire hazard is detected. The panel may also provide visual and audible alerts to operators in the event of a fire.
Suppression Agents: Various suppression agents may be employed depending on the type of fire and the specific requirements of the CNC machine. Common suppression agents include:
Water: Water-based suppression systems utilize sprinklers or nozzles to dispense water onto the affected area, cooling the fire and extinguishing it.
Dry Chemicals: Dry chemical agents, such as dry powder or ABC powder, are effective against Class A, B, and C fires. These agents work by interrupting the chemical reaction of the fire.
Carbon Dioxide (CO2): CO2 systems release a high-pressure stream of carbon dioxide gas, displacing oxygen and smothering the fire without leaving residue that could damage sensitive equipment.
Foam: Foam-based suppression systems generate a blanket of foam to suppress the fire and prevent reignition.
Activation Mechanism: Upon detection of a fire, the control panel triggers the release of the suppression agent through valves or nozzles positioned at key locations within the CNC machine enclosure. The activation mechanism may be automatic or manual, depending on the system's design and safety requirements.
Emergency Shutdown: In addition to activating the suppression system, the CNC machine's fire safety protocol may include an automatic or manual emergency shutdown feature. This function halts all machine operations to prevent the spread of fire and protect personnel from harm.
Monitoring and Maintenance: Regular inspection, testing, and maintenance of the fire suppression system are essential to ensure its proper functioning in an emergency. This includes checking sensors, verifying agent levels, and replacing any faulty components.
*Your information is safe with us.
Fire Fighting System Type | Fire Suppression Systems |
Fire Extinguisher Type | Modular Automatic Type |
Usage/Application | Industrial |
Material | Mild Steel |
Fire Suppression Type | Fire Extinguisher |
Certification | ISO |
Automation Grade | Automatic |
I Deal In | New Only |
Country of Origin | Made in India |
A bus fire suppression system is a specialized safety mechanism designed to detect and suppress fires that may occur in buses. These systems are crucial for ensuring passenger safety and preventing catastrophic incidents on public transportation vehicles. Here's an overview of how these systems typically work:
Detection: Bus fire suppression systems usually incorporate advanced detection mechanisms such as smoke detectors, heat sensors, or flame detectors. These sensors continuously monitor various areas of the bus for any signs of fire or overheating.
Alert: Upon detecting a potential fire hazard, the system activates audible and visual alarms to alert the driver and passengers of the danger. This early warning allows for prompt action to be taken before the situation escalates.
Suppression: The suppression system typically employs one or more methods to extinguish the fire or suppress its growth. Common suppression agents include:
Fire Extinguishers: Some systems may include manual fire extinguishers placed strategically throughout the bus, allowing passengers or the driver to tackle small fires immediately.
Automatic Fire Suppression Systems: These systems automatically release fire suppression agents, such as dry chemicals, foam, or water mist, upon detecting a fire. The suppression agent is dispersed in the affected area to smother the flames and prevent the fire from spreading.
Halon Systems (less common): In the past, Halon gas was widely used for fire suppression due to its effectiveness in extinguishing fires without leaving residue. However, due to environmental concerns regarding its ozone-depleting properties, alternatives are now more commonly used.
Emergency Procedures: In addition to fire suppression, bus fire safety systems often include protocols and procedures for evacuating passengers safely in the event of a fire. This may involve emergency exits, evacuation routes, and instructions for passengers to follow during an evacuation.
Monitoring and Maintenance: Regular inspection, maintenance, and testing of the fire suppression system are essential to ensure its proper functioning. This includes checking sensors, ensuring the integrity of suppression agents, and verifying that all components are in working order.
Overall, bus fire suppression systems play a critical role in enhancing the safety of passengers and minimizing the risk of fire-related incidents on buses. These systems are designed to detect fires swiftly, alert occupants, and deploy suppression measures to contain or extinguish the fire before it causes significant harm or damage.
Fire Fighting System Type | Fire Suppression Systems |
Fire Suppression Type | Total Flooding |
Extinguishing Agent | Carbon Di Oxide |
Brand | Firetek |
Cylinder Height (mm) | As per design |
Design | On request |
Fire Class | BC |
Certification | CE, VDS |
Usage/Application | Electrical Room, Chemical Room, Unmanned area |
I Deal In | New Only |
Condition | New |
Country of Origin | Made in India |
CO2 flooding systems, also known as carbon dioxide fire suppression systems, are a type of fire suppression system commonly used in industrial and commercial settings. These systems are designed to quickly extinguish fires by flooding the protected area with carbon dioxide gas, displacing oxygen and suppressing the combustion process. CO2 flooding systems are particularly effective for extinguishing fires involving flammable liquids and electrical equipment, as they do not leave behind residue that could damage sensitive equipment.
Here's how CO2 flooding systems typically work:
Detection: The system detects the presence of fire through various means such as heat detectors, smoke detectors, or flame detectors.
Activation: Once a fire is detected, the CO2 flooding system is activated either manually or automatically depending on the setup and the level of automation in the system.
Release of CO2: Carbon dioxide stored in high-pressure cylinders or tanks is released into the protected area. The release can be accomplished through a network of pipes and nozzles strategically located throughout the space.
Displacement of Oxygen: As CO2 is discharged, it fills the protected area, displacing oxygen. Since fire requires oxygen to sustain combustion, the reduction in oxygen concentration helps extinguish the fire.
Fire Suppression: With the oxygen concentration lowered, the combustion process is interrupted, leading to the suppression of the fire.
Post-Discharge Ventilation: Once the fire is extinguished, the area may need to be ventilated to remove excess CO2 and restore safe breathing conditions for personnel.
CO2 flooding systems offer several advantages, including:
However, there are also considerations and potential drawbacks to using CO2 flooding systems, such as the risk of asphyxiation in confined spaces if adequate ventilation is not provided after discharge and the potential for harm to personnel if they are present in the protected area during discharge due to the rapid displacement of oxygen.
Overall, CO2 flooding systems are an effective fire suppression option for many applications, but proper design, installation, and maintenance are crucial to ensure their safe and effective operation.
Minimum Order Quantity | 1 Set |
Fire Fighting System Type | Fire Suppression Systems |
Packaging Type | Corrugated Rolls |
System type | Total Flooding System |
Condition | New |
Brand | FireTEK |
Material | Mild Steel |
Environment Temp | Ambient Temp. |
Certification | FM Approved, CE, UL Approved |
Fire Suppression Type | Cylinder, Pipeline, Fire Extinguisher |
Power Source | No Power Supply Require |
Operating Temperature Limit | 90 Degree + |
Working Pressure | 15 Kg/cm2, 16-18 Bard |
Medium Type | Clean Agent, Foam Monitor, Water Monitor, Dry Power |
Cylinder Size (Kg) | 2, 4, 6 Kg. |
Usage/Application | Industrial |
Installation Services Required | Yes |
Automation Grade | Automatic |
Alarm | Audio Visual Alarm |
Design | Tailor Made |
Portable | Portable |
Is It Abrasion Resistance | Yes |
I Deal In | New Only |
Chemical Agent | Clean Agent |
Mounted | Wall Mounting, Panel Mounting |
Country of Origin | Made in India |
Fire suppression systems are crucial components of fire safety infrastructure designed to quickly detect, control, and extinguish fires in various environments, such as buildings, vehicles, and industrial facilities. These systems are essential for protecting lives, property, and assets from the devastating effects of fires.
Here are some key aspects of fire suppression systems:
Detection: Fire suppression systems typically incorporate detectors such as smoke detectors, heat detectors, or flame detectors to sense the presence of a fire. These detectors trigger the activation of the suppression system when they detect signs of a fire.
Activation: Upon detecting a fire, the suppression system activates automatically or manually, depending on the system's design and configuration. Automatic activation systems are designed to trigger without human intervention once the fire is detected, while manual systems require someone to activate them.
Suppression Agents: Fire suppression systems utilize various agents to extinguish fires. Common suppression agents include water, dry chemicals, foam, gas (such as carbon dioxide or halon), and mist. The choice of suppression agent depends on factors such as the type of fire risk, the environment, and the materials present.
Delivery Systems: The suppression agent is delivered to the fire through a network of pipes or tubing, often with strategically placed nozzles or sprinklers. These delivery systems ensure that the suppression agent reaches the fire quickly and effectively.
Control Panels: Fire suppression systems are typically controlled by central control panels that monitor the status of detectors, activation devices, and suppression agents. Control panels provide visual and audible alerts in the event of a fire and may include manual controls for system testing and activation.
Maintenance and Testing: Regular maintenance and testing are essential to ensure the reliability and effectiveness of fire suppression systems. This includes inspection of detectors, testing of control panels, and servicing of suppression agents to ensure they are ready to perform when needed.
Regulatory Compliance: Fire suppression systems are subject to regulatory requirements and standards to ensure their design, installation, and maintenance meet safety standards. Compliance with these regulations is essential for ensuring the effectiveness of fire suppression systems and minimizing the risk of fire-related hazards.
Overall, fire suppression systems play a vital role in fire safety by quickly containing and extinguishing fires, thereby preventing their spread and minimizing damage to property and life.
*Your information is safe with us.
Fire Fighting System Type | Fire Suppression Systems |
Usage/Application | Industrial |
System type | Pre-Engineered System |
Type | Fire Extinguisher, Alarm System |
Certification | FM Approved, UL Approved |
Installation Services Required(Y/N) | Yes |
I Deal In | New Only |
Country of Origin | Made in India |
A fume cabinet suppression system is a safety feature designed to mitigate the risk of fire or explosion in laboratory fume hoods or cabinets where hazardous materials are handled. These suppression systems typically consist of sensors, detectors, and a suppression agent delivery system.
Here's how it generally works:
Detection: The system includes sensors or detectors that monitor for signs of fire or increased levels of heat within the fume cabinet.
Alarm: Upon detecting a potential fire or hazard, the system activates an alarm to alert laboratory personnel of the danger.
Suppression Agent Activation: If the threat is confirmed, the suppression system releases a fire suppression agent. The type of agent used can vary but may include water, inert gases (such as nitrogen or argon), or chemical agents (such as halon substitutes or clean agents like FM-200).
Suppression: The suppression agent is released into the fume cabinet to extinguish the fire or prevent its spread.
Shutdown: After the fire is suppressed or the hazard is mitigated, the system may shut down to prevent further release of the suppression agent and allow for safe cleanup and investigation of the incident.
Fume cabinet suppression systems are crucial for laboratories handling flammable or hazardous materials, as they help protect both personnel and property from the risks associated with fires or explosions. It's essential to regularly inspect, maintain, and test these systems to ensure they remain effective in case of an emergency.
Fire Fighting System Type | Fire Suppression Systems |
Brand | FIRETUFF |
System type | Pre-Engineered System |
Usage/Application | Industrial |
Installation Services Required | Yes |
I Deal In | New Only |
Country of Origin | Made in India |
A CNC machine suppression system is a safety mechanism designed to mitigate the risk of fires caused by various factors such as electrical faults, overheating of components, or improper use of the equipment. These systems typically employ a combination of detection, suppression, and alarm mechanisms to ensure the safety of the CNC (Computer Numerical Control) machining environment.
Key components of a CNC machine suppression system may include:
Fire Detection Sensors: These sensors are strategically placed within the CNC machine and its surrounding area to detect signs of fire or excessive heat. They can be optical sensors, heat detectors, or smoke detectors.
Alarm Systems: Upon detecting a potential fire hazard, the suppression system triggers audible and visual alarms to alert personnel in the vicinity. This allows for quick response and evacuation if necessary.
Fire Suppression Agents: Various suppression agents can be utilized, such as dry chemical powders, clean agents (like FM-200 or Novec 1230), or water-based systems, depending on the nature of the CNC machine and the materials being worked on. The suppression agent is released to extinguish or control the fire.
Control Panel: The control panel serves as the central hub for monitoring the system's status, receiving inputs from sensors, and initiating suppression actions when required. It also provides interfaces for manual control and system configuration.
Emergency Shutdown: In case of a fire or other hazardous situation, the CNC machine suppression system may have the capability to automatically shut down the machine to prevent further escalation of the incident.
Remote Monitoring: Some advanced suppression systems offer remote monitoring capabilities, allowing operators to monitor the status of the system and receive alerts even when they are not physically present near the CNC machine.
Implementing a CNC machine suppression system is crucial for ensuring workplace safety and protecting valuable equipment from damage due to fire incidents. Additionally, adherence to relevant safety standards and regulations is essential when designing and installing such systems to ensure their effectiveness and compliance.
Fire Fighting System Type | Fire Suppression Systems |
Capacity | 2 Kg |
Certification | Fire detection using heat-sensing tubing (UL Listed) |
Size/Dimension | 2 kg, 4.5 kg, 9 kg, 15 kg and 22 kg |
Operating Temperature Limit | 60 BAR |
Suppression System | SUPPRESSION CO2 AGENT |
I Deal In | New Only |
Country of Origin | Made in India |
RAKSHAK is a specialized In-Cabinet Fire Suppression System, utilizing CO2 extinguishing agent.
Description
· RAKSHAK” CO2 fire suppression system
· Cylinder Sizes: 2Kg to 18 Kg
· Operating Pressure: 60 BAR
· Automatic IHP Valve in Brass construction
· Diffuser nozzles: Brass/SS construction
· Fire detection using heat-sensing tubing (UL Listed)
· The fire detection tube on charged condition automatically fills CO2 from the cylinder. This is a unique feature where one does not require additional Nitrogen cylinder to charge the detection tube
RAKSHAK is a specialized In-Cabinet Fire Suppression System, utilizing CO2 extinguishing agent.
Description
· RAKSHAK” CO2 fire suppression system
· Cylinder Sizes: 2Kg to 18 Kg
· Operating Pressure: 60 BAR
· Automatic IHP Valve in Brass construction
· Diffuser nozzles: Brass/SS construction
· Fire detection using heat-sensing tubing (UL Listed)
· The fire detection tube on charged condition automatically fills CO2 from the cylinder. This is a unique feature where one does not require additional Nitrogen cylinder to charge the detection tube